Instrument catalogue
30 instruments across 9 families, made by instrument factories in Chuzhou and Tianchang. Prices are issued per order because range, material and connection change the model. Search by model or parameter, filter by family, then open the product page for the full table.
Nothing in the catalogue matches that word. Clear the search, or write to us with the parameter you need — the factories build more than this page lists.
Bourdon tube pressure gauge, Ø100
The general-purpose gauge most lines are still specified with: dry or liquid-filled case, 0–40 bar.
Process pressure gauge, Ø150
Large dial, all-stainless wetted parts, ±1.0 % FS — for operators who read it from the walkway.
Pressure transmitter, 4–20 mA
Piezoresistive transmitter with a 316L diaphragm; 0–16 bar, two-wire, HART on request.
Differential pressure transmitter
Two-port DP cell for filter monitoring and flow by orifice; 0–250 kPa, square-root output available.
Utility gauge, Ø63, glycerine filled
The small liquid-filled gauge that survives a pump skid: 0–25 bar, ±2.5 % FS, brass internals.
Adjustable pressure switch
Mechanical switch with a settable trip point and SPDT contact, 0.5–10 bar, for interlock and alarm duty.
K-type thermocouple assembly
Ø6 mm 304 sheath, 0–1100 °C, fixed thread and 2 m lead — the assembly local factories make by the thousand.
PT100 resistance thermometer
Three-wire PT100 in a Ø6 316L sheath, −50 to 200 °C, for the accuracy a thermocouple cannot hold.
Bimetallic thermometer, Ø100
No power, no wiring: a bimetal coil in a stainless stem, −20 to 150 °C, read straight off the dial.
Head-mount temperature transmitter
Fits inside a standard connection head: PT100 or thermocouple in, 4–20 mA out, HART optional.
Electromagnetic flowmeter, DN50
Full-bore magnetic meter, PTFE liner, 4–20 mA plus pulse, no straight-run penalty on slurries.
Vortex flowmeter, DN25
Steam, gas or liquid in one body; no moving parts, 4–20 mA and totaliser, DN25 to DN300.
Rotameter, DN25
A glass tube and a float: the cheapest honest flow reading on a small line, 0.1–10 m³/h of water.
Turbine flowmeter, DN40
Tight tolerance on clean low-viscosity liquids: ±1.0 %, 4–20 mA and pulse out.
Magnetic level gauge
A magnetic float in a sealed tube moves red and white flags outside it — readable in daylight, at pressure.
Radar level transmitter, 26 GHz
Non-contact level to 15 m through dust, steam and foam; 4–20 mA, no moving parts in the tank.
Ultrasonic level transmitter
0–8 m on water, slurry and chemicals, with a temperature-compensated echo; cheap and non-contact.
Hydrostatic level transmitter
Submersible 316L diaphragm on a vented cable: level from pressure, 0–5 m H2O, 4–20 mA.
Digital panel meter
4-digit meter with universal input, relay alarms and a 24 V loop supply — the panel's front line.
PID temperature controller
Auto-tuning PID with relay or SSR output and a second alarm; the thermostat replacement that holds ±0.5 °C.
Paperless recorder, 16 channel
Sixteen inputs on one 7-inch screen, logged to SD card — the record a paper chart used to be.
pH / ORP transmitter
Glass electrode, 0–14 pH, 4–20 mA and two relays; the dosing loop in a wastewater plant.
Conductivity transmitter
Two-electrode cell from 0–2000 µS/cm, temperature-compensated, with a 4–20 mA output for the RO skid.
Thermocouple compensation cable, KX
KX-type pair with overall shield, 2 × 0.5 mm², sold by the metre or cut to the run.
Shielded control cable, 4 × 1.5 mm²
Four-core shielded control cable for 4–20 mA and 24 V circuits, cut to length, PVC or LSZH.
Channel cable tray, 100 mm
Perforated channel tray, 1.5–3.0 mm steel, hot-dip galvanised, with covers and bends cut to the drawing.
Ladder cable tray, 200 mm
Ladder tray on 300 mm rungs for heavy cable runs and airflow; galvanised steel, straight and bends.
Instrument junction box, 304 SS
IP66 enclosure with 24 terminals, cable glands and a mounting plate; the box at the end of the cable run.
Digital multimeter, 600 V CAT III
True-RMS meter with a 4–20 mA range, continuity and a backlit display — bench to field.
Insulation resistance tester, 5 kV
250 V to 5 kV test voltages with PI and DAR — the cable test before energising.
Documents: datasheet and calibration certificate are issued with each quotation on request.