Rotameter, DN25
A glass tube and a float: the cheapest honest flow reading on a small line, 0.1–10 m³/h of water.
Line illustration. Photographs of the supplied unit and its nameplate are sent with the quotation.
Overview
A vertical variable-area meter with a borosilicate tube and a stainless float. It needs no power and no calibration loop, and the scale can be printed for air, water or a specific gas.
Specifications
| Range | 0.1–10 m³/h water (air ranges to order) |
|---|---|
| Accuracy | ±2.5 % FS |
| Body | 304 SS with borosilicate tube |
| Connection | G1/2 to G1 female |
| Pressure | up to 1.0 MPa |
| Temperature | 0–120 °C |
Typical values for this family. The datasheet issued with your quotation states the exact figures for the unit supplied.
Features
- Scale printed for the medium you actually run
- Needle valve integrated on the inlet
- Tube replaceable without changing the body
Options
- Alarm reed switch on the float
- Acrylic body for low-pressure air
- Panel or wall mounting bracket
Typical applications
- Dosing and sampling lines
- Cooling water to a single mould or seal
- Purge flow on instruments
More in Flow
Same family, same quotation process. Open a product to compare parameters side by side.
Electromagnetic flowmeter, DN50
Full-bore magnetic meter, PTFE liner, 4–20 mA plus pulse, no straight-run penalty on slurries.
Vortex flowmeter, DN25
Steam, gas or liquid in one body; no moving parts, 4–20 mA and totaliser, DN25 to DN300.
Turbine flowmeter, DN40
Tight tolerance on clean low-viscosity liquids: ±1.0 %, 4–20 mA and pulse out.